Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13638257

- Product Categories
- Friendly Links
Information Name: | Efficient mixed flow fan, oblique flow fan, air conditioning Echo (View) |
Published: | 2015-01-06 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | 1. The fan performance by performance on the performance table access swf oblique flow fan, the performance is listed in the table in the most efficient range of performance, according to the flow is divided into six performance point efficient mixed flow fan, according to prevail in the selection of the performance table . 2. Qualified performance fan factory is in full flow at rated pressure value does not exceed ± 5%. 3. Performance Selection is based on fan performance tables under standard conditions, regardless of the technical documentation or performance requirements are standard state order prevail, the standard state atmospheric B = 101325Pa, atmospheric temperature t = 20oC, relative humidity φ = 50% of the time air condition, when the actual conditions of use does not comply with the above formula for conversion in accordance with relevant. 4. Fan installation can be divided into vertical and horizontal, vertical installation as required when ordering, if the flow rate, pressure and other performance parameters special request, I will provide you with further design and production plant. Deal with the various components to install a wind turbine installation 1. conduct a comprehensive inspection, parts are complete mixed flow fan, join the parts are tightened. 2. The fan should be installed to keep the horizontal position of the fan, the fan and the ground connection to the combination of surface and out of the wind pipe, etc., should be adjusted to make it natural, not have to force fit connection, plus the weight of the pipe is not allowed in the fan assembly on, and should be checked for internal fans have fallen into the legacy tools and other objects. 3. Turn the fan must be checked after installation of the impeller, if the impeller casing grazing phenomenon, if found wrong, you must adjust the fan using measures should be rain in the open air. The fan should run test after passing the examination conducted in general, in order to prevent motor overload, before fans start the flow control valve is closed, so no load at startup, then gradually open the valve, as a full load or design point run . 5. When the fan running if there is severe vibration, shock and other anomalies mixed mixed flow fan, you must immediately stop checking. 6. found operating point shift caused by overloading the motor, in order to prevent motor overload can flow control valve off a small motor in the rated current. 7. Regular clear the internal fan fouling dirt and other impurities, and to prevent corrosion. Efficient mixed flow fan, oblique flow fan, air conditioning Echo (View) Ltd provided by Texas Echo air conditioning equipment. Echo Air Conditioning Equipment Co., Texas (www.dzaike.com) is a professional, "central air-conditioning equipment," the company. Since its inception, we adhere to the "good faith, sound management" approach, the courage of healthy competition in the market, so that the "Echo conditioned" brand has a good reputation. We adhere to the "service first, customers first" principle, so air conditioning Echo won the trust of customers congregation in central air conditioning, and establish a good corporate image. Special Note: This information is for reference pictures and information, please contact us to obtain the most accurate information, thank you! |
Admin>>>
You are the 30948 visitor
Copyright © GuangDong ICP No. 10089450, Air Conditioning Equipment Co., Texas Echo All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 30948 visitor
Copyright © GuangDong ICP No. 10089450, Air Conditioning Equipment Co., Texas Echo All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility